ORC turbines / Cooling-to-power

Cooling-to-power: ElectraTherm Active Cooler

For sites that must cool hot water anyway, such as engines, compressors and biogas plants, and that want the cooler to make power.

✉️ Send heat-source data 🎧 Book Teams Appointment

Active Cooler AC800

The ElectraTherm Active Cooler AC800 replaces or relieves a radiator. It covers 70–100 % of the cooling load and generates electricity whenever the cooling demand allows. It goes from off to full load in 60 seconds, and if the ORC trips it keeps cooling in bypass.

ElectraTherm Active Cooler AC800

Technical data

ModelElectrical outputCooling capacityHot-water temperatureHot-water flow
Active Cooler AC800up to 75 kWe gross, 65 kWe netup to 800 kW70–150 °C3–15 l/s

2.3 × 10.1 × 2.0 m, 6,500 kg; skid version 2.4 × 9.5 × 1.75 m, 4,800 kg · heat loads above 800 kW may need a custom design · gaseous heat sources need an extra heat exchanger.

Pilot: biogas plant in Poland

Engine jacket water feeds the first Active Cooler. It generates 35 kWe and removes an 8 kW radiator load: 45 kW of new net power and a 5.5 % gain in site efficiency.

ElectraTherm case: an AC800 on a 1.6 MW engine running 8,000 h a year produces 616 MWh a year.

Do you cool engine jacket water today?

Send us the heat load, temperatures and operating hours.

✉️ Send heat-source data 🎧 Book Teams Appointment